JOURNAL OF CLINICAL SURGERY ›› 2018, Vol. 26 ›› Issue (11): 818-821.doi: 10.3969/j.issn.10056483.2018.11.006
Previous Articles Next Articles
Received:
Online:
Published:
Abstract: Objective To investigate and analysis the treatment of Guide wirecapture technique in the endovascular stent repair for Stanford B aortic dissection.Method 67 consecutive patients with complex Stanford B aortic dissection.Our patients cohort were divided into those applied with retrograde technique endovascular stent repair(group A,n=57) and anterograde Guide wirecapture technique(group B,n=10).Compared the general characteristics,true and false lumen diameter,Xray exposure time,total surgical time and analysis the correlation between intimal rupture number and Xray exposure time.Result There was no significant difference in success rate between group A and B(85.1% vs 100.0%,P>0.05).The intimal rupture number(Group A:1.9±0.8,Group B:3.4±0.8,P<0.05),tissue or organ poor perfusion case of group B(60.0%) was higher than that of group A(15.8%,P<0.05).The false lumen diameter of group B[(29.6±9.1)mm] was wider than that of group A[(21.7±7.4)mm,P<0.05)].3 patients of group A suffer from the left upper limb poor perfusion syndrome and conducted with rightleft axillary artery bypass.1 patient of group B suffered reversely tore after operation and progressed to A type aortic dissection,then conducted with Sun’ surgery and been completely reversed.The operation time and Xray exposure time of group B[(174.2±26.2)min and(522.9±67.4)s] was longer than that of groupA[(147.8±22.6)min and(267.1±29.1)s,P<0.05)].We conclude that the Xray exposure time may positively correlated with the intimal rupture number(R2=0.47,95%CI: 0.1051~0.9197,P<0.05).In most cases,followup was maintained and no obvious leakage occurred. Conclusion We concluded that the increased intimal rupture number may increase the degree of surgical difficulty and the Xray exposure time.Guide wirecapture technique in the endovascular stent repair for complicated Stanford B aortic dissection may be a safe and reliable manner.
Key words: aortic dissection, guide wirecapture technique, intimal rupture, 〓ray exposure time
CHENG Lianghao, YIN Xiaoqing, XU Zhaojun, et al. Application analysis of guide wirecapture technique in the endovascular stent repair for Stanford B aortic dissection[J].JOURNAL OF CLINICAL SURGERY, 2018, 26(11): 818-821.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://www.lcwkzz.com/EN/10.3969/j.issn.10056483.2018.11.006
http://www.lcwkzz.com/EN/Y2018/V26/I11/818
Cited