JOURNAL OF CLINICAL SURGERY ›› 2021, Vol. 29 ›› Issue (7): 639-642.doi: 10.3969/j.issn.1005-6483.2021.07.014

Previous Articles     Next Articles

One-stop hybrid surgery for complex thoracic and abdominal aortic disease

  

  1. Department of Cardiac and Great Vascular Surgery,the Central Hospital of Wuhan,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430014,China
  • Online:2021-07-20 Published:2021-07-20

Abstract: Objective To summarize the experience and results of applying Hybrid technology to treat thoracoabdominal aortic diseases in our hospital.
Methods We counted 10 patients with thoracoabdominal aortic lesions admitted to our hospital from October 2016 to October 2020,including one case of thoracoabdominal aortic aneurysm and nine cases of thoracoabdominal aortic dissection.According to the extent of aortic disease involvement,visceral artery bypass surgery at the corresponding involvement site was performed first,followed by endoluminal overlapping stent repair of the aorta in one stage.The follow-up period ranged from 3 to 48 months,with a median follow-up time of 24.5 months.
Results All surgeries were successfully completed,including 10 cases of first-stage endovascular repair.The average operating time for the same operation was 8.5 h,and the average endovascular operation time was 2.0 h.There were no fatal cases 30 days after surgery,5 cases of acute kidney injury,5 cases of acute liver injury,3 cases of intestinal obstruction,and 1 case of intestinal fistula in the perioperative period.One of the patients with intestinal fistula died 3 months after surgery.By the end of follow-up,all patients had no endoleaks or paraplegia.All bypass vessels were patent and free of stenosis during the follow-up period.
Conclusion The hybridization technique is feasible for the treatment of complex thoracoabdominal aortopathy,with satisfactory near- to mid-term outcomes and long-term results awaiting further follow-up.

Key words: hybrid surgery, thoracoabdominal aortic disease, aortic dissection, aortic aneurysm

[1] . Logistic regression analysis of shortterm and midterm outcomes and risk factors of complications between hybrid operation and Bracket Elephant trunk technique for complex type B aortic dissection [J]. JOURNAL OF CLINICAL SURGERY, 2021, 29(6): 526-529.
[2] . Comparison of the efficacy and safety of Stanford type B aortic dissection with Hybrid and fenestration TEVAR reconstruction of the left subclavian artery [J]. JOURNAL OF CLINICAL SURGERY, 2020, 28(6): 522-526.
[3] . Effect of endovascular repair on aortic remodeling and prometaphase survival in patients with complicated stanford b aortic dissection [J]. JOURNAL OF CLINICAL SURGERY, 2020, 28(6): 527-529.
[4] . The endovascular management of complex abdominal aortic aneurysms [J]. JOURNAL OF CLINICAL SURGERY, 2020, 28(6): 587-589.
[5] . Analysis of prognosis and risk factors of acute kidney injury after stanford type A aortic dissection surgery [J]. JOURNAL OF CLINICAL SURGERY, 2020, 28(5): 467-470.
[6] CHEN Lin, WEI Xiang, JIANG Dingsheng, et al.. The aberrant expression of PDLIM3 in aorta of patients with aortic dissection and its clinical significance [J]. JOURNAL OF CLINICAL SURGERY, 2020, 28(3): 243-246.
[7] . Individual thoracic endovascular aortic repair strategy for management of type B aortic dissection with an aberrant right subclavian artery [J]. JOURNAL OF CLINICAL SURGERY, 2020, 28(11): 1012-1015.
[8] TIAN Xiangang, YANG Min, FANJidan.. Study on the correlation between D-dimer and C-reactive protein and geometric parameters of the pseudolumen of DeBakey type III aortic dissecting aneurysm to judge the prognosis [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(6): 504-507.
[9] . Feasibility of personalized hypotension to reduce the incidence of aortic dissection [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(2): 178-179.
[10] . Clinical study on the treatment of Stanford A aortic dissection by onestop hybridization surgery [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 943-945.
[11] CHENG Lianghao, YIN Xiaoqing, XU Zhaojun, et al. Application analysis of guide wirecapture technique in the endovascular stent repair for Stanford B aortic dissection [J]. JOURNAL OF CLINICAL SURGERY, 2018, 26(11): 818-821.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(10): 772 .
[2] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(11): 888 .
[3] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(12): 905 .
[4] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(12): 934 .
[5] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(6): 422 .
[6] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(8): 596 .
[7] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(9): 700 .
[8] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(9): 728 .
[9] . [J]. JOURNAL OF CLINICAL SURGERY, 2017, 25(10): 754 -757 .
[10] . [J]. JOURNAL OF CLINICAL SURGERY, 2017, 25(12): 919 .