JOURNAL OF CLINICAL SURGERY ›› 2019, Vol. 27 ›› Issue (11): 938-942.doi: 10.3969/j.issn.1005-6483.2019.11.005

Previous Articles     Next Articles

Application of 3D guidance technique in endovascular aortic repair

  

  • Online:2019-11-20 Published:2019-11-20

Abstract: Objective:To evaluate the feasibility and technical advantages of 3D guidance technique in endovascular aortic repair.Methods:This was a retrospective single center study.From November 2016 to December 2018,38 patients undergoing thoracic endovascular aortic repair(TEVAR)or endovascular aortic repair(EVAR)with assistance of 3D guidance technique and intraoperative DynaCT.Meanwhile,40 patients were received standard endovascular aortic repair(control group).The proximal anchorage area was insufficient for branch vascular reconstruction in 16 patients.Comparative analysis of intraoperative and followup data between the two groups was undertaken.Results:The results of this study showed that compared with conventional DSA,3D guidance technique and intraoperative DynaCT reduced contrast dose(TEVAR 60.31ml vs 73.34ml P=0.032;EVAR 83.43ml vs 94.83ml P=0.013),intraoperative radiation dose(TEVAR 293.04mGy vs 385.71mGy P=0.002;EVAR 431.84mGy vs 584.51mGy,P=0.043),number of radiography(TEVAR 2.36 vs 3.56,P=0.016;EVAR 3.43 vs 4.01,P=0.029),operation time(TEVAR 64.09min vs 71.42min P=0.001;EVAR 142.14min vs 153.39min P=0.057),meanwhile,reduced the risk of postoperative aortarelated reintervention(2.63% vs 10% P=0.042),meeting the precise requirements for anatomical positioning and immediate effect determination during endovascular aortic repair.Conclusion:3D guidance technique improves the accuracy during positioning in complex endovascular aortic repair,could reduce aorticrelated reintervention rate,radiation exposure time and contrast dose.Further studies and development are needed to obtain optimal image quality and higher precision.


Key words: endovascular aortic repair, 3D guidance, DynaCT

No related articles found!
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(10): 829 .
[2] . [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(10): 904 -906 .
[3] . [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 925 -927 .
[4] . [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 928 -930 .
[5] . [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 931 -934 .
[6] . [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 935 -937 .
[7] . Clinical study on the treatment of Stanford A aortic dissection by onestop hybridization surgery[J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 943 -945 .
[8] . Analysis of risk factors for thoracic incision poor healing after cardiovascular surgery[J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 946 -949 .
[9] . Detection trend and distribution characteristics of 1721 cases of nonspecific invasive breast cancer  [J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 950 -952 .
[10] . Study on the effect of warmed,humidified carbon dioxide insufflation versus standard carbon dioxide in laparoscopic general surgery[J]. JOURNAL OF CLINICAL SURGERY, 2019, 27(11): 953 -956 .