JOURNAL OF CLINICAL SURGERY ›› 2019, Vol. 27 ›› Issue (4): 305-308.doi: 10.3969/j.issn.1005-6483.2019.04.012

Previous Articles     Next Articles

Anatomical study of the femur internal and external condyle notch line as the femoral intramedullary localization point used in total knee arthroplasty

  

  1. Department of Orthopedics,Suzhou Municipal Hospital,Suzhou 215000,China
  • Received:2018-08-22 Online:2019-04-20 Published:2019-04-20

Abstract: Objective To study the feasibility and accuracy of the femur internal and external condyle notch line as the femoral intramedullary localization point used in total knee arthroplasty(TKA).Methods 64 patients with TKA were randomly divided into the observation group and the control group,32 cases(32 knees)in each group.The observation group was positioned according to the interlocking point between the internal and external condyle notch line and the extension line of the medial lateral condyle of femur.The control group was positioned with traditional technique.The distance between the location points and the anatomical axis of the femur,the femoral external rotation angle and the lower limb force line deviation were observed.Results The average distance between the anatomical axis of femur and the highest point of the intercondylar notch ceiling was(14.27±2.48)mm.The average distance in the observation group was(1.1±0.37)mm,and the distance in the control group was(3.22±1.45)mm,and there was significant difference between the two groups(P<0.05).The deviation of lower extremity force line and femoral prosthesis valgus angle were measured.In the observation group the deviation was(2.49±1.27)°,and the control group was(3.81±1.74)°,and there was significant difference between the two groups(P<0.05).In the observation group,the femur prosthesis valgus angle was(88.6±2.71)°,and the control group was(86.7±4.17)°.there was significant difference between the two groups(P<0.05).Conclusion The interlocking point between the internal and external condyle notch line and the extension line of the medial lateral condyle of femur was a more accurate position for the femoral intramedullary localization point used in total knee arthroplasty,it could provide a satisfactory postoperative femoral prosthesis alignment.

Key words: total knee arthroplasty, the femur internal and external condyle notch, localization point, anatomy

No related articles found!
Viewed
Full text
672
HTML PDF
Just accepted Online first Issue Just accepted Online first Issue
0 0 0 0 0 672

  From Others local
  Times 82 590
  Rate 12% 88%

Abstract
426
Just accepted Online first Issue
0 0 426
  From Others
  Times 426
  Rate 100%

Cited

Web of Science  Crossref   ScienceDirect  Search for Citations in Google Scholar >>
 
This page requires you have already subscribed to WoS.
  Shared   
  Discussed   
[1] . [J]. JOURNAL OF CLINICAL SURGERY, 0, (): 481 .
[2] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(10): 760 .
[3] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(10): 794 .
[4] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(11): 841 .
[5] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(11): 844 .
[6] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(11): 859 .
[7] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(11): 865 .
[8] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(12): 896 .
[9] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(12): 916 .
[10] . [J]. JOURNAL OF CLINICAL SURGERY, 2016, 24(12): 927 .